Sub-Zero Incoming Water Isolation Valve Integrated Designer
Sub-Zero Catalog ID: S1292

Sub-Zero Incoming Water Isolation Valve Integrated Designer

Main water-control valve positioned before the filter

Genuine Sub-Zero part used on these models:
IC-18FI, IC-24C, IC-24CI, IC-24FI, IC-30FI, IC-36FI +13 more View all 19 compatible models Show fewer compatible models IC-18FI, IC-24C, IC-24CI, IC-24FI, IC-30FI, IC-36FI, IT-30FI, IT-30CI, IT-30CIID, IT-36CI, IT-36CIID, IW-30CI, DEC2450FI, DEC3050FI, DEC3650FI, DET3050FI, DET3050CI, DET3050CIID, and DET3650CI
In Stock
$265.10
We’ll ask for your model or serial number after you add this item to your cart (optional).
Item subtotal: $265.10
Free UPS Ground in the 48 contiguous states. AK/HI shipping is calculated at checkout. Expedited shipping is available.
Part Order Guarantee

Every order is manually reviewed by our parts experts before processing. If you provide your model or serial number and we ship the wrong part, we’ll cover the return or exchange, including a prepaid return label.

Need help before ordering? Email Parts Research

OEM part description

This genuine Sub-Zero isolation valve controls incoming household water before it reaches the appliance water filter and downstream water components. It serves as the first electrically controlled valve in the internal water path, allowing or stopping water flow as required.

Part details

Because this valve is upstream from the filter and other water valves, a restriction or failure can affect more than one water function. A failing isolation valve may cause little or no water flow, slow icemaker filling, reduced dispenser flow on applicable models, leakage, or difficulty shutting off the internal water supply.

Specifications / Important Notes:

  • Part Type: Incoming water isolation valve
  • Electrical Supply: 120-volt AC
  • Water-System Position: Upstream of the water filter
  • Primary Role: Opens and closes incoming appliance water flow
  • Configuration: Single-valve design
  • Components: Genuine Sub-Zero
  • Important: The icemaker fill valve and dispenser valves used downstream are separate components.

Tech Tip: When several water functions are weak or not working at the same time, check household water pressure and the isolation valve before assuming multiple downstream components have failed. Since this valve is near the beginning of the water path, a restriction here can affect everything after it.