Sub-Zero Refrigerator Compressor Start Relay & Overload Kit
245RFD, 249R, 249RP, 424, 424-2, 427 +55 more View all 61 compatible models Show fewer compatible models
245RFD, 249R, 249RP, 424, 424-2, 427, 427-2, 427R, 427R-2, 430, 430-2, 501R, 511, 532, 542, 550, 561, 590, 601R, 601RG, 601R-2, 601RG-2, 601R-3, 601RG-3, 611, 611G, 611-2, 611G-2, 611-3, 611G-3, 632, 632-2, 632-3, 642, 642-2, 642-3, 648PRO, 650, 650G, 650-2, 650G-2, 650-3, 650G-3, 661-2, 661-3, 680, 685-2, 685-3, 690, 695-2, 695-3, 700BR, 700BR-2, 700BR-3, 700TR, 700TR-2, 700TR-3, 700TC/I-2, 700TC/I-3, 736TR-3, and 736TC/I-3Compressor starting relay and overload protection components for the Embraco EMI30HER
Part Order Guarantee
Every order is manually reviewed by our parts experts before processing. If you provide your model or serial number and we ship an incorrect part, we'll cover the return or exchange, including a prepaid return label.
Our technician-backed team is available to help with parts questions, installation guidance, and troubleshooting.
Part Description
This genuine Sub-Zero OEM two-piece compressor electrical set includes one start relay and one overload protector for the Embraco EMI30HER refrigerator compressor.
The start relay engages the compressor's starting circuit, while the overload protector helps protect the compressor motor against excessive electrical current and overheating. Both components mount at the compressor's electrical terminals and are supplied together as an Expert Appliance Pro technician-recommended set.
Part details
A failing refrigerator compressor start relay or overload protector can prevent the compressor from starting or cause it to shut down unexpectedly. Common symptoms include repeated clicking from the compressor area, humming without starting, or rising refrigerator temperatures because the compressor isn't running.
These two electrical components work together in the compressor starting and protection circuit. Replacing a damaged relay or overload with the correct OEM component is important for proper compressor operation.
This set is designed specifically for the Embraco EMI30HER compressor. Your current compressor identification tag must read EMI30HER. Earlier or later production versions of some listed Sub-Zero models may use a different compressor and different electrical components.
Specifications / Important Notes
- Includes: One refrigerator compressor start relay and one compressor overload protector
- Compressor application: Embraco EMI30HER
- Factory Original Sub-Zero OEM Replacement Parts
- Set configuration: Two individual OEM components supplied together by Expert Appliance Pro
- Important: Refrigerator model alone does not establish the correct relay, overload, or the compressor currently installed in your appliance. Your current compressor identification tag must read EMI30HER; This will not fit a freezer compressor
- Installation: These components are intended to replace the relay and overload and will not correct an internally damaged or failed compressor. These are non-returnable parts. Electrical service should be performed by a qualified appliance service technician
Tech Tip — Refrigerator Compressor Start Relay & Overload Kit
If your Sub-Zero refrigerator is warm and you hear repeated clicking or humming near the compressor, the start relay or overload protector may be failing. These symptoms can also indicate a compressor or electrical problem. Check the compressor identification tag before ordering this set, particularly on older Sub-Zero models that were manufactured with more than one compressor type.